If you are in search of part numbers like 024-11619, 1423157-6, 7012ACL, 7012ACLGZ, DELW11R115V60CY, and others that fall under the NSN 5945-00-584-9251, we have you covered with the catalog and procurement resources provided on this page. At the top of the page, you will be able to review a number of details and data that pertain to this particular NSN, while available offerings are listed out below. If any items on our NSN 5945-00-584-9251 catalog interest you, be sure to request a quote from our staff at your earliest convenience. You can do this by submitting a Request for Quote (RFQ) form through our website or by getting in touch with our team via phone or email.
As an ASAP Semiconductor platform operating with quality as a focus, all NSN 5945-00-584-9251 parts we stock come from trusted manufacturers and undergo any necessary inspections or testing prior to shipment. Additionally, every purchase you make will come delivered with all applicable qualifying certifications or manufacturing trace documentation. Aside from such commitments, we also strive to provide customers procurement solutions that equally balance competitive pricing and timely fulfillment. With so much to offer, choose ASAP MilSTD for NSN 5945-00-584-9251 supplies and more.
Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-584-9251 (005849251) |
NCB Code | USA (00) |
Manufacturer | Johnson Controls Inc, Tyco Electronics France Sas, Tyco Electronics Agastat Relays, Amerace Ltd |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
024-11619 | johnson controls inc | relay electromagnetic | 66935 | RFQ |
1423157-6 | tyco electronics france sas | relay electromagnetic | f0286 | RFQ |
7012ACL | tyco electronics agastat relays | relay electromagnetic | 89020 | RFQ |
7012ACLGZ | amerace ltd | relay electromagnetic | f5846 | RFQ |
DELW11R115V60CY | tyco electronics agastat relays | relay electromagnetic | 89020 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 3.250 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.520 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.090 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 45.392 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 1.50 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 15.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 480.0 AC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 11 SCREW ALL FUNCTIONS |
Relevant Components for NSN - 5945-00-584-9251, 5945005849251 | ||||
5930-01-558-3633 (5930015583633) | 5998-01-464-6151 (5998014646151) | 5935-01-506-9572 (5935015069572) | 5910-01-007-5962 (5910010075962) | |
5962-01-085-4176 (5962010854176) | 5905-01-416-9093 (5905014169093) | 5935-01-682-9240 (5935016829240) | 5950-00-193-8677 (5950001938677) | |
5950-01-127-8658 (5950011278658) | 5930-01-201-1993 (5930012011993) | 5998-00-153-4334 (5998001534334) | 5910-00-816-3875 (5910008163875) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.