Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number 172061-000, a Bae Systems Inc item with the NSN 5950009450652 that is listed alongside the description “Transformer Power.” If you are interested in part number 172061-000 and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number 172061-000 is specifically listed with the NSN 5950-00-945-0652, and this code can be used to determine that it falls under FSC 5950 Coils and Transformers. Additionally, while tracing back to Bae Systems Inc, this NSN part was specifically produced under CAGE Code 81413. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-945-0652 Item PartTypeName: TRANSFORMER,POWER | 5950 | 009450652 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
73C828-003 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.552 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.990 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 3RD GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 4TH GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 2ND GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 3RD GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES 4TH GROUP |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 1.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 1.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 13.86 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 3.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 346.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 41.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
FEAT | SPECIAL FEATURES | TWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 25 TURRET |