Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number A68C-10, a Crane Carrier Company item with the NSN 5925015037845 that is listed alongside the description “Circuitbreaker.” If you are interested in part number A68C-10 and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number A68C-10 is specifically listed with the NSN 5925-01-503-7845, and this code can be used to determine that it falls under FSC 5925 Circuit Breakers. Additionally, while tracing back to Crane Carrier Company, this NSN part was specifically produced under CAGE Code 03533. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-503-7845 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015037845 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
68C10 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | Body Style | SINGLE POLE TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC SINGLE LOCATION AND 10.0 AMPERES DC SINGLE LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
ABXD | Bushing Length | 0.500 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION AND 50.0 DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
ADAT | Body Width | 0.560 INCHES NOMINAL |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED STUD |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
AKPX | Pole Quantity | 1 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 1000.0 SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CXCY | Part Name Assigned By Controlling Agency | CIRCUIT BREAKER, MANUAL RE-SET, 10 AMP |
CPRW | Actuator Function | RESET |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRT | Manual Actuator Type And Quantity | 1 PUSH BUTTON |
ADTV | Case Material | PLASTIC |
THSD | Thread Series Designator | UNEF |
TTQY | Terminal Type And Quantity | 2 QUICK DISCONNECT, MALE |
AJWX | Mounting Surface To Terminal End Distance | 1.660 INCHES NOMINAL |
ADAQ | Body Length | 1.380 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.438 INCHES |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.840 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 1000 PCT SINGLE LOCATION AND 0.780 MAXIMUM AT 1000 PCT SINGLE LOCATION |
CMLP | Thread Quantity Per Inch | 28 |
CPRP | Ultimate Trip Time Per Pole In Seconds | 0.150 MINIMUM SINGLE LOCATION AND 0.780 MAXIMUM SINGLE LOCATION |
AGAV | End Item Identification | NSN 2320-01-452-5579, TRUCK TRACTOR |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote