Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number 4502256ZT2N, a Detroit Switch Inc item with the NSN 5930013734999 that is listed alongside the description “Switch Thermostatic.” If you are interested in part number 4502256ZT2N and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number 4502256ZT2N is specifically listed with the NSN 5930-01-373-4999, and this code can be used to determine that it falls under FSC 5930 Switches. Additionally, while tracing back to Detroit Switch Inc, this NSN part was specifically produced under CAGE Code 19278. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-373-4999 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 013734999 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
90C02-2182 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABMK | OVERALL WIDTH | 3.094 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.250 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 5.312 INCHES NOMINAL |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.000 AC AT SEA LEVEL FIRST VOLTAGE |
STYL | STYLE DESIGNATOR | RECTANGULAR |
ABHP | OVERALL LENGTH | 5.812 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.312 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 480.000 INCHES NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
ADAQ | BODY LENGTH | 4.938 INCHES NOMINAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 TWO CIRCUIT,DOUBLE BREAK/DOUBLE MAKE,ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | SCREW |
FREQ | FREQUENCY IN HERTZ | 60.000 FIRST VOLTAGE |
ABKW | OVERALL HEIGHT | 3.250 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
AXGY | MOUNTING METHOD | FLANGE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote