Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number C4439, a Electronic Transformer Corp item with the NSN 5950007549954 that is listed alongside the description “Transformer Audio Frequency.” If you are interested in part number C4439 and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number C4439 is specifically listed with the NSN 5950-00-754-9954, and this code can be used to determine that it falls under FSC 5950 Coils and Transformers. Additionally, while tracing back to Electronic Transformer Corp, this NSN part was specifically produced under CAGE Code 72149. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-754-9954 Item PartTypeName: TRANSFORMER,AUDIO FREQUENCY | 5950 | 007549954 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
C4439 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.703 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.120 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.807 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.817 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYW | IMPEDANCE RATING IN OHMS | 5024.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ MAXIMUM SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CRBZ | WINDING OPERATING CURRENT | 125.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACYE | TRANSFORMER FUNCTION | MODULATION |
ACYW | IMPEDANCE RATING IN OHMS | 335.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ACZH | PRIMARY TO SECONDARY TURN RATIO | 1 TO 15 SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAT | BODY WIDTH | 1.219 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.391 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 20.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
TEST | TEST DATA DOCUMENT | 95750-8050000628 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TURRET |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote