Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number T1613, a Magnetika Inc item with the NSN 5950006483986 that is listed alongside the description “Transformerpower.” If you are interested in part number T1613 and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number T1613 is specifically listed with the NSN 5950-00-648-3986, and this code can be used to determine that it falls under FSC 5950 Coils and Transformers. Additionally, while tracing back to Magnetika Inc, this NSN part was specifically produced under CAGE Code 1L8V1. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-648-3986 Item PartTypeName: TRANSFORMER,POWER | 5950 | 006483986 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
26409 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 54.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.312 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.062 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.125 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 65.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 2.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB,SOLDER LUG |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.