Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number 711518-13, a Raytheon Company item with the NSN 5925011312137 that is listed alongside the description “Circuit Breaker.” If you are interested in part number 711518-13 and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number 711518-13 is specifically listed with the NSN 5925-01-131-2137, and this code can be used to determine that it falls under FSC 5925 Circuit Breakers. Additionally, while tracing back to Raytheon Company, this NSN part was specifically produced under CAGE Code 05869. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-131-2137 Item Description: Circuit Breaker | 5925 | 011312137 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
711518-13 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
AKPX | Pole Quantity | 3 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND SALT SPRAY PROOF |
CPLM | Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES AC ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
AJWX | Mounting Surface To Terminal End Distance | 2.625 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 AC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE THREE |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CSSX | Switch Current Rating And Type In Amps | 10.0 AC AND 10.0 DC |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
THSD | Thread Series Designator | UNC |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
ADAT | Body Width | 2.265 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT EACH POLE |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 65.0 DC |
AAJE | Thread Pitch Diameters | +0.1177/+0.1214 INCHES |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
BBRJ | Special Handling Feature | MAGNETIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
PKWT | Unpackaged Unit Weight | 11.100 OUNCES |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
MRC | Decoded Requirement | Clear Text Reply |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.