Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number APL-11-1REC2-64-103-MA, a Sensata Technologies Inc item with the NSN 5925013072007 that is listed alongside the description “Circuit Breaker.” If you are interested in part number APL-11-1REC2-64-103-MA and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number APL-11-1REC2-64-103-MA is specifically listed with the NSN 5925-01-307-2007, and this code can be used to determine that it falls under FSC 5925 Circuit Breakers. Additionally, while tracing back to Sensata Technologies Inc, this NSN part was specifically produced under CAGE Code 81541. With our services and dedication to simple procurement in mind, get started with us today!
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
CSSX | Switch Current Rating And Type In Amps | 10.0 AC AND 3.0 DC |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 7.400 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
BBRJ | Special Handling Feature | MAGNETIC |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRQ | Reset Method | MANUAL |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
ADAT | Body Width | 1.500 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 50.0 DC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
ADTV | Case Material | PLASTIC |
THSD | Thread Series Designator | ISO S |
AJWX | Mounting Surface To Terminal End Distance | 2.475 INCHES NOMINAL |
ADAQ | Body Length | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
CQQR | Thread Pitch In Millimeters | 0.5 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.500 MAXIMUM AT 200 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CRTK | Switch Terminal Type | QUICK DISCONNECT, MALE |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CQJX | Nominal Thread Size | 3.0 MILLIMETERS |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |