Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number 299-4-21016-4, a Sensata Technologies Inc item with the NSN 5925015708514 that is listed alongside the description “Circuit Breaker.” If you are interested in part number 299-4-21016-4 and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number 299-4-21016-4 is specifically listed with the NSN 5925-01-570-8514, and this code can be used to determine that it falls under FSC 5925 Circuit Breakers. Additionally, while tracing back to Sensata Technologies Inc, this NSN part was specifically produced under CAGE Code 81541. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-570-8514 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015708514 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
299-4-21016-4 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPLM | Maximum Continuous Load Current Rating Per Pole | 55.0 AMPERES DC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 DC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 DC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 DC SECOND LOCATION |
FREQ | Frequency In Hertz | 60.0 THIRD LOCATION |
FREQ | Frequency In Hertz | 60.0 FIRST LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CXCY | Part Name Assigned By Controlling Agency | CIRCUIT BREAKER-SERIES/RELAY,TRIP |
FREQ | Frequency In Hertz | 60.0 SECOND LOCATION |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
CPRT | Manual Actuator Type And Quantity | 4 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES/RELAY TRIP ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 55.0 AMPERES DC FIRST LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 55.0 AMPERES DC SECOND LOCATION |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AKPX | Pole Quantity | 4 |
FEAT | Special Features | OPERATING TEMPERATURE -40 TO +85DEG C;4TH POLE CURRENT NOT USED, VOLTAGE NOT USED, TRIP 24VDC HOLDING COIL, FREQ DC |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CPRX | Actuator Position Designation | AT EACH POLE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote