Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number 190014-1, a Shallcross Inc item with the NSN 5905011572728 that is listed alongside the description “Resistor Network Fixed Wirewound.” If you are interested in part number 190014-1 and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number 190014-1 is specifically listed with the NSN 5905-01-157-2728, and this code can be used to determine that it falls under FSC 5905 Resistors. Additionally, while tracing back to Shallcross Inc, this NSN part was specifically produced under CAGE Code 54294. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-157-2728 Item PartTypeName: RESISTOR NETWORK,FIXED,WIRE WOUN | 5905 | 011572728 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
NR1708 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0/10.0 |
AAPP | ELECTRICAL RESISTANCE | 199.956 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 200.000 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 200.016 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 33.3333 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.100/0.100 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 65.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | 0.0/60.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 10 |
AARB | TERMINAL TYPE | PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.150 INCHES MINIMUM AND 0.250 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.180 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.650 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.250 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | ISOLATED ARRAY |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.100 TOTAL NETWORK |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 1ST INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 HIGHEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 2 2ND INTERMEDIATE RESISTANCE VALUE |
STYL | STYLE DESIGNATOR | DUAL INLINE |
TEST | TEST DATA DOCUMENT | 49956-895817 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.