Thank you for taking an interest in the various military and defense parts, aerospace parts, and other items that we offer. You have reached the RFQ page for part number WE-3757, a Wems Electronics item with the NSN 5950012346441 that is listed alongside the description “Reactor Transformer.” If you are interested in part number WE-3757 and wish to learn more about your purchasing options, be sure to submit the form below at your earliest convenience while supplying us with important information concerning your needs and restrictions alike. Once we have a chance to receive and review your completed form, a member of our staff will reach out to you in 15 minutes or less to present a tailored solution for your comparisons.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that shopping with us is as simple as possible, we make it easy to identify and procure exact items by listing parts alongside all applicable designations and information. For example, part number WE-3757 is specifically listed with the NSN 5950-01-234-6441, and this code can be used to determine that it falls under FSC 5950 Coils and Transformers. Additionally, while tracing back to Wems Electronics, this NSN part was specifically produced under CAGE Code 26543. With our services and dedication to simple procurement in mind, get started with us today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-234-6441 Item PartTypeName: REACTOR-TRANSFORMER | 5950 | 012346441 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
DB101836 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHY | TURN QUANTITY | 112 2ND COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 180 3RD COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 180 3RD COMPONENT SINGLE SECONDARY |
ABHY | TURN QUANTITY | 36 2ND COMPONENT SINGLE SECONDARY |
ABHY | TURN QUANTITY | 70 1ST COMPONENT SINGLE WINDING |
ABKW | OVERALL HEIGHT | 0.950 INCHES NOMINAL |
ACYV | INDUCTANCE RATING | 0.05 MILLIHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING |
ACYV | INDUCTANCE RATING | 0.35 MILLIHENRIES NOMINAL 3RD COMPONENT SINGLE PRIMARY |
ACYV | INDUCTANCE RATING | 0.35 MILLIHENRIES NOMINAL 3RD COMPONENT SINGLE SECONDARY |
ACYV | INDUCTANCE RATING | 1.75 MILLIHENRIES NOMINAL 2ND COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL 1ST COMPONENT |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL 3RD COMPONENT |
ACZB | FREQUENCY RATING | 50.0 KILOHERTZ NOMINAL 2ND COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 2ND COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 3RD COMPONENT |
ADAQ | BODY LENGTH | 2.250 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.050 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.450 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING AND WINDING TURNS 1ST COMPONENT SINGLE WINDING |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE PRIMARY AND WINDING TURNS 2ND COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE SECONDARY AND WINDING TURNS 2ND COMPONENT SINGLE SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE PRIMARY AND WINDING TURNS 3RD COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE SECONDARY AND WINDING TURNS 3RD COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 1 SECONDARY 2ND COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 1 SECONDARY 3RD COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.00631 INCHES AMERICAN WIRE GAGE 2ND COMPONENT SINGLE PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.00631 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.00631 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 1ST COMPONENT SINGLE WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 2ND COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.05 AMPERES AC NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 0.05 AMPERES AC NOMINAL 3RD COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.1 AMPERES AC NOMINAL 2ND COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.32 AMPERES AC NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 0.35 AMPERES AC NOMINAL 1ST COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.070 2ND COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 2.000 2ND COMPONENT SINGLE SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 2.800 3RD COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 2.800 3RD COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.00 AC VOLTS NOMINAL 2ND COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 4.50 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
FEAT | SPECIAL FEATURES | THIS INSEPARABLE UNIT CONTAINS 2 TRANSFORMERS AND 1 REACTOR |
TTQY | TERMINAL TYPE AND QUANTITY | 12 PIN |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.